Perle Systems Sds4 Bedienungsanleitung Seite 277

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 460
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 276
276
Channels
Pulse Mode When Output is set to Pulse, you can specify the manner of the pulse.
Data Options:
z Continuous—Continuously pulses active and inactive.
z Count—Pulses an active/inactive sequence for the specified number of
times.
Default: Continuous
Pulse Count The channel output will pulse for the specified number of times; each count
consists of an active/inactive sequence.
Default: 1
Inactive Signal
Width
How long the channel will remain inactive during pulse mode.
Range: 1-9999 x 100 ms
Default: 1 (100 ms)
Active Signal
Width
How long the channel will be active during the pulse mode.
Range: 1-9999 x 100 ms
Default: 1 (100 ms)
Delay When a deactivate command is issued, a delay is implemented before the
command is executed.
Range: 1-9999 x 100 ms
Default: 1 (100 ms)
Failsafe Action When there has been no I/O activity within the specified time (set in the I/O
Interfaces, Settings on the Failsafe Timer tab) and the
Failsafe Timer is
triggered.
Data Options:
z None—The state of the Digital/Relay output remains the same, no change.
z Activate Output—Activates the channel.
z Deactivate Output—Deactivates the channel.
Default: None
Seitenansicht 276
1 2 ... 272 273 274 275 276 277 278 279 280 281 282 ... 459 460

Kommentare zu diesen Handbüchern

Keine Kommentare