Perle Systems IOLAN SCS Bedienungsanleitung Seite 108

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 408
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 107
Serial Port Profiles
108 IOLAN SDS/SCS/STS User’s Guide, Version 3.6
Duplex Used with a EIA-485 serial interface, specify whether the serial port is Full
Duplex
(communication both ways at the same time) or Half Duplex
(communication in one direction at a time).
Default: Full
TX Driver Control Used with a EIA-485 serial interface, if your application supports RTS
(Request To Send), select this option. Otherwise, select
Auto.
Default: Auto
Flow Control Defines whether the data flow is handled by the software (Soft), hardware
(
Hard), Both, or None. If you are using SLIP, set to Hard only. If you are
using
PPP, set to either Soft or Hard (Hard is recommended). If you select
Soft with PPP, you must set the ACCM parameter when you configure PPP for
the
Serial Port.
Data Options: Soft, Hard, Both, None
Default: None
Enable Inbound
Flow Control
Determines if input flow control is to be used.
Default: Enabled
Enable Outbound
Flow Control
Determines if output flow control is to be used.
Default: Enabled
Monitor DSR Specifies whether the EIA-232 signal DSR (Data Set Ready) should be
monitored. This is used with modems or any device that sends a DSR signal.
When it is monitored and the IOLAN detects a DSR signal, the line profile is
started. If both
Monitor DCD and Monitor DSR are enabled, both signals must
be detected before the line profile is started.
Default: Disabled
Monitor DCD Specifies whether the EIA-232 signal DCD (Data Carrier Detect) should be
monitored. This is used with modems or any other device that sends a DCD
signal. When it is monitored and the IOLAN detects a DCD signal, the line
profile is started. If both
Monitor DCD and Monitor DSR are enabled, both
signals must be detected before the line profile is started.
Default: Disabled
Enable Line
Termination
Used with EIA-422 and EIA-485 on SDS rack mount IOLAN models,
specifies whether or not the line is terminated; use this option when the serial
port is connected to a device at the end of the serial network.
Default: Disabled
Enable Echo
Suppression
This parameter applies only to EIA-485 Half Duplex mode. All characters will
be echoed to the user and transmitted across the serial ports. Some EIA-485
applications require local echo to be enabled in order to monitor the loopback
data to determine that line contention has occurred. If your application cannot
handle loopback data, echo suppression should be enabled.
Default: Disabled